Article

Understanding paper and board variation, part 2: variance component analysis

Variance component analysis of 12 measured CD strips: the mean basis weight profile with its 95 % confidence band, the strips as a heatmap and each strip's level.

Variance component analysis separates persistent cross-direction variation from changes along the machine, helping identify where corrective action is needed.

Two reels can have the same standard deviation of basis weight or caliper and still have quite different problems. In one, the same profile shape repeats across the width all the time. In another, the level drifts along the machine. In a third, the profile simply does not repeat. Each calls for a different corrective action, and a single standard deviation does not tell them apart.

Variance component analysis (VCA) answers this from a set of CD strips cut across the full width of the same parent reel. We measure such strips in our laboratory for both basis weight and caliper, so the same question can be asked of both properties.

Three kinds of variation

CD variation is the profile that repeats in every strip: a heavier tending side, a thick spot in the middle, a streak that stays in place. This is the part that CD control and machine adjustments can correct.

MD variation here means changes in the average level from one strip to the next, such as a slow drift in basis weight over the sampled length of the reel. It does not cover all MD variation. Fast periodic variation, such as barring or the frequencies of rolls, felts and pumps, falls between or within the strips and needs an MD measurement instead.

Residual variation is what is left: a profile that changes shape from strip to strip, streaks that wander sideways, local disturbances. It is not necessarily random noise, but it does not repeat, so CD control cannot follow it.

Try it

The figure below analyzes simulated strips the way Tapio Analysis does, and each slider changes one component. The heatmap shows every strip as a row, with the mean CD profile above it and each strip's level beside it. The residual stdev at the bottom shows where across the width the profile changes most from strip to strip.

Variance component analysis of a set of strips

Sheet
×1.0
×1.0
×1.0
VCA Statistics

Standard deviations, BW [g/m²]

BW [g/m²]% of mean
MD Stdev0.320.40 %
CD Stdev0.350.44 %
Total Stdev0.580.72 %
Residual Stdev0.320.41 %
MD F-ratio8944
CD F-ratio30

F-ratio: the component's mean square over the residual's. The higher it is, the more clearly the component stands out from the changing variation.

8081CD profile [g/m²]95 % confidenceFilteredUnfilteredMeasured79.079.580.080.581.081.5BW [g/m²]8081MD profile[g/m²]135791113151719212325Strip02460.00.20.4Distance [m]Residual stdev [g/m²]95 % rangeRMS
25 CD strips of a 7.2 m wide sheet, sampled every 0.8 mm as a Tapio Analyzer measures them, and filtered 0–30 1/m and analyzed as in the Variance Component Analysis window of Tapio Analysis. The sheet has three parts with their own sliders: differences in level from strip to strip (MD), a profile shared by every strip (CD), and variation that changes from strip to strip (residual). Point at the plots to read them.

With the CD slider at zero, the vertical stripes disappear from the heatmap. A large MD component turns it into horizontal bands, and a large residual makes the strips look unlike each other and widens the confidence band of the mean profile.

The statistics box also gives the F-ratios of TAPPI T 545, each component compared with the residual. The higher the CD F-ratio, the more clearly the persistent profile stands out: here it drops from about 30 to a few when the CD slider is set to zero. Read the ratios as a measure of size rather than a formal significance test. With dense sampling, neighboring points are not independent, so changing variation alone gives a CD F-ratio above 1, and the MD F-ratio is large because each strip level averages thousands of points.

What the answer tells you

If most of the variation is in the CD component, the profile is stable and correcting it is likely to reduce the total. The mean CD profile shows where the correction is needed. If the residual dominates, adjusting the CD profile alone will not help much: the question is what makes the profile unstable, and the residual stdev plot shows where across the width to look. A large MD component points to changes over time, such as stock or flow conditions, rather than to the CD profile.

Comparing basis weight and caliper from the same strips is often the most useful step. A machine can have a good basis weight profile and still a clear persistent caliper profile. That suggests the thickness variation comes from pressing, calendering or other processes acting on thickness rather than from the mass distribution.

How the measurement is made

TAPPI T 545 is the standard method for basis weight. Twenty consecutive layers are cut from the reel into sheets of 200 × 300 mm, conditioned and weighed one by one, and an analysis of variance gives the components. The method is reliable but laborious, about 340 sheets for a 4.6 m wide reel, and it gives one value per 250 mm of width for basis weight only.

At Tapio the strips are joined into one roll and measured on a Tapio Analyzer, sampled every millimeter or less, for basis weight, caliper and density from the same points. Tapio Analysis then calculates the components with the T 545 statistics. The measurement is not the gravimetric procedure, so for a direct comparison with a T 545 result the profiles are filtered to the same scale.

QCS reel statistics come from a scanner crossing the web diagonally, so some MD variation appears as CD variation, and they are calculated differently (TAPPI TIP 1101); they are not directly comparable with a strip analysis.

VCA shows how much variation there is, of which kind and where, but not its wavelengths or physical cause. The CD spectrum, in Part 3 of this series, and knowledge of the machine take the analysis further.

Testing your own reel

Send us at least 20 full-width CD strips from one parent reel, and we return the measured basis weight and caliper profiles, the variance components and our reading of them. The sample preparation instructions explain how to cut and mark the strips.

References

  • TAPPI T 545 om-23, Cross-machine grammage profile measurement (gravimetric method). TAPPI, 2023.
  • TAPPI TIP 1101-01, Calculation and partitioning of variance using paper machine scanning sensor measurements. TAPPI, 2017.

Send us your samples

Send us MD rolls or CD strips. You get the measured profiles, a report of the findings and a review with a Tapio specialist.