TAPIO PDA - Process Data Analysis
1. Tapio PDA - Process Data Analysis Using Digital Import To WinTapio
- Software package, no hardware required
2. Tapio Proma - Process Data Analysis Using Analog Import To WinTapio
- Proma hardware & WinTapio software
3. Tapio PMA/Profiler - Paper Quality & Quality Variation Analysis
- PMA/Profiler hardware & WinTapio Software
TAPIO® PDA - Process Data Analysis
Measurement parameters
On-line:
- paper machine speed: 1300 m/min
- measurement step: 0,001 s = 21,7 mm
- measurement time: 131 s = 2838 m
- aperture size: 13 mm
- radiation source: Pm 147
Tapio:
- measurement speed: 1 m/s
- measurement step: 12,8 mm
- measurement length: 3836 m
- aperture size: 5 mm
- radiation source: Pm 147
>> Unfiltered MD profile
>> MD spectrum
Summary: Case 1
- In this case on-line and Tapio measurements were almost identical
- On-line system can measure long term BW variation as accurately
as Tapio analyzer
- The resolution of the on-line system is not high enough to measure
short term variation
>>View full PDA presentation